Ultra Electronics, NSPI
Request Quote
Toll Free (US)  +1 800-880-9333

Power Supply Modules (PSMs)

Several EOTec 2000 power supplies are offered to conform to available power sources. Depending on the model selected, these modules will accept a DC or AC power input and provide DC voltage to any module engaged to its backplane connector. The power supply part numbers always begin with 2A. For example, the 2A08 is the DC power supply.

Key Selection Criteria:

  • Will AC or DC power be available at the installation site?
  • Is redundancy required?

Module Selection Guide:

Part No:
Data Sheet (PDF)
2A06 2A16 2A08 2A18
Nominal Input Voltage: 120/240 VAC at 50/60 Hz & 125 VDC 120/240 VAC at 50/60 Hz & 125 VDC 24VDC 24VDC
Input Current: 250mA 250mA 400mA 400mA
Input Fuse: 400mA
Slow-blow
400mA
Slow-blow
400mA
Slow-blow
400mA
Slow-blow
Regulated Output Power: 9VDC
1.1A Max.
9VDC
1.1A Max.
9VDC
1.1A Max.
9VDC
1.1A Max.
Alarm Relay: No Yes (1) No Yes (1)
Indicators: Power On
(Green LED)
Power On
(Green LED)
Power On
(Green LED)
Power On
(Green LED)
Operating Temperature: -40 to 85°C -40 to 85°C -40 to 85°C -40 to 85°C
Operating Rel. Humidity: 0 to 90%
non-cond.
0 to 90%
non-cond.
0 to 90%
non-cond.
0 to 90%
non-cond.
Height: 3.9 inches 3.9 inches 3.9 inches 3.9 inches
Width: 1.8 inches 1.8 inches 0.9 inches 0.9 inches
Depth: 4.9 inches 4.9 inches 4.9 inches 4.9 inches
CE Mark Yes Yes Yes Yes
UL/cUL Recognized Component Yes Yes No No
UL/cUL Listed for Class I, Div. 2 Hazardous Locations No No Yes Yes
FM Approved for Class I, Div. 2 Hazardous Locations No No Yes Yes
Install Instructions (PDF) 2A06 2A16 2A08 2A18

Note (1): Alarm Contact - 1ea. Form C, 175VDC, 1 Amp Continuous

© 2010 Weed Instrument Co., Inc. d/b/a Ultra Electronics, Nuclear Sensors & Process Instrumentation     All rights reserved.     Privacy Statement     Legal Disclaimer     Valid XHTML